Stoney Cedar Ltd.
Flame n'Aqua Shield - are your cedar products protected?


Flame n' Aqua Shield Overview Flame n' Aqua Technical Reports Report One Report Two Report Three Flame n' Aqua Shield Technical Information

 Agra Earth and Environmental Logo
Technical Report No. 4
24 March 1999

PROJECT: EVALUATION OF FIRE RETARDANT PROPERTIES OF
FLAME n' AQUA SHIELD

SUBJECT: STANDARD TEST METHOD FOR FIRE TESTS OF ROOF COVERINGS (ASTM E108-91A/93)



Control Panel 1 - Industry Conventional Fire Treatment
Test Panel 2 - Flame n' Aqua Shield
Formula 102GM Spray

Type of Test
Test Panel 1
Comments
Test Panel 2
Comments
Spread of Flame
Total Fire/Smoke Duration

9 minutes
Pass, no hole
15 minutes
Pass, no hole
Area Effected/Charred
60 sq in
Pass, no hole
56 sq in
Pass, no hole
Flying Brand
Number of Flying Brands

0
Pass
1
Pass
Intermittent Flame
Total Fire/Smoke Duration

17 minutes
Pass
1 minute
Pass, some
Area Effected/Charred
84 sq in
Pass
14 sq in
cracking sound
Burning Brand
Total Fire/Smoke Duration

55 minutes
Fail, test terminated at 55 minutes
83 minutes
Pass, no holes
No. of Brands Burned Through
7
Fail, test terminated at 55 minutes
0
Pass, no holes
No. of Brands Extinguished
13
Fail, test terminated at 55 minutes
20
Pass, no holes

Conditions of Classification (Class C)
At no time during or after the intermittent flame, spread of flame, or burning brand tests shall:
- any portion of the roof covering material be blown or fall off the test deck in form of flaming or glowing brands that continue to glow after reaching the floor, or
- the roof deck be exposed or portions of the roof deck fall away in the form of particles that continue to glow after reaching the floor or sustained flaming of the underside of the deck.
- the flaming shall not spread beyond 13 ft. and there shall be no significant lateral spread of flame from the path directly exposed to the test flame.

Comments
- Material Tested: Class 1 Taper Sawn Cedar Shingles installed on a 1.17 m. x 1.07 m. deck
- Type of Treatment: Test panel sprayed with 2 coats FAS Formula 102GM (rate 50 sq ft/litre), Air Cured < 1 week, Rain Tested for 12 weeks
- Date Test Panel Constucted and Treated: 98-06-22 ; Date Fire Tested: 99-01-07
- Test Method Used: Modified ASTM E108 - 91a (Ref. AGRA Report VA-4263, Section 3.0)


 Stoney Cedar Logo

Stoney Cedar Ltd.
19564 - 60th Avenue
Surrey, B.C., Canada
V3S 3S7

E-mail: service@stoneycedar.com

Yard/Office Tel: (604) 534-6331
Fax: (604) 534-6775

Accts Tel: (604) 583-4839
Fax: (604) 584-3508